Summary

Hardware that supports monitoring will display different information about hardware status, like temperature, voltage, current, fan-speed, etc.

Example on CCR1072-1G-8S+ device:

          cpu-overtemp-check: yes
      cpu-overtemp-threshold: 100C
  cpu-overtemp-startup-delay: 1m
             cpu-temperature: 46C
           power-consumption: 62.9W
          board-temperature1: 31C
          board-temperature2: 34C
                psu1-voltage: 12.1V
                psu2-voltage: 0V
                psu1-current: 5.2A
                psu2-current: 0A
                  fan1-speed: 6375RPM
                  fan2-speed: 6436RPM
                  fan3-speed: 6375RPM
                  fan4-speed: 6467RPM

Warning: For feature availability on RouterBOARD products check mikrotik.com



Voltage

Routers that support voltage monitoring will display supplied voltage value. In CLI/Winbox it will display volts. In scripts/API/SNMP this will be dV or value showed in CLI/Winbox multiplied by 10

Note: Routers that have PEXT and PoE power input are calibrated using PEXT, as a result, value showed over PoE can be lower than input voltage due to additional ethernet protection chains.


Note: If old revision CRS112, CRS210 and CRS109 devices are powered with PoE - Health will show correct voltage only up to 26.7V. If higher voltage will be used - Health will show constant 16V.


Temperature

Routers that support temperature monitoring will display temperature reading. In CLI/Winbox it will display degrees Celsius. Using scripts/API/SNMP this value will be shown in CLI/Winbox multiplied by 10. There are various temperature sensors depending on the device. These sensors may refer to: cpu-temperature, pcb-temperature, sfp-temperature. Device tested ambient temperature range you can find in specification description at mikrotik.com. Tested ambient temperature range is temperature in which device can be physically located. It is not the same as temperature which reports system health monitor!

Fan control and behavior


/system health set

Using this menu users will be able to control fan behaviour on TILE architecture devices.

Note: Improved FAN stability starting from version 6.45.5.


There are three parameters that may affect fan behaviour: PoE-out consumption, SFP temperature and CPU temperature. As soon as one of the parameters exceeds the optimal value the, fans are started.

PoE-out consumption

If a device has PoE-out, then the fan RPM will change as described below:

PoE-out loadRPM % of max FAN speed (DC fans)
0%..24%FAN speed 0%
25%..46%FAN speed 25%
47%..70%FAN speed 50%
71%..92%FAN speed 75%
93%..FAN speed 100%

For devices with PWM fans, the speed will linearly increase or decrease from 9..88% (note: below 100W the fan RPM=0)

Limited manual fan-control option

Note: Starting from RouterOS version 7.9beta4 limited manual fan-control options have been added for CRS3xx, CRS5xx and CCR2xxx devices.

Fan behavior can be manipulated using the settings section of system health:

/system health settings set 

Available parameters are described below:

ParameterDescription
fan-full-speed-temp

Sets the temperature value upon which the fan speed will be increased to the maximum possible rpm.

Reads temperature from CPU, PHY, SWITCH and SFP and adjusts fan speed based on the component with the highest temperature.

Value range for this setting is -273 to 65

fan-target-tempSets the target temperature for the hottest component. Based on this setting adjusts fan behavior to hold temperatures in target range.
Value range for this setting is -273 to 65
fan-min-speed-percent

Sets the minimum percentage of fan speed thus not allowing fans to have a lower rpm than this value.

Value range for this setting is 0 - 100

fan-control-interval

Sets the actual temperature data read interval to get temperature values from CPU, PHY, SWITCH and SFP.

Value range of this setting is 5 to 30

*NOTE: THIS SETTING DIRECTLY AFFECTS CPU USAGE

CPU and SFP temperature

If CPU or SFP temperatures exceed 58C, the fans will start to spin. The higher the temperature, the faster the fans will spin. For devices with PWM fans, as the CPU or SFP temperatures exceed 58C, the fans will linearly increase their RPM to try to keep the temperature at 58C if possible. For devices with DC fans, as the CPU or SFP temperatures exceed 58C, the fans will start spinning but at a higher minimum RPM by default. This may result in cooling the device to the point where the fans turn-off completely. After which the temperature may slowly increase to 58C and the fans will turn on again. Currently, there is one exception. The S+RJ10 modules have a temperature threshold of 65C before they trigger the fans. Since it's a higher temperature threshold, the fans will start spinning at a higher initial speed to cool the device.

Note: All readings are approximate and may not be 100% precise. Their purpose is to ~inform users about possible/upcoming failures.