Make sure not to include the cascade-ports and control-ports in any routing or bridging configurations. These ports are recommended only for a CB and PE usage.

Packet flow


Controller Bridge settings and monitoring

...

Additionally, each PE device port interface can be monitored on the port menu, use print and monitor commands to see more details.

...

Property

Description

device (name)Automatically assigned PE device name.
name (name)Automatically assigned PE port name.
pcid (integer)Automatically assigned port identifier.
port-status (dev-inactive | not-added | ok)PE port status.
rate (bps)Data rate of the connection.
status (link-ok | no-link | unknown)PE port link status.

The Controller Bridge can monitor the PoE-out related information from Port Extenders on the port poe menu, use print and monitor commands to see more details. For more information regarding PoE-out, please visit the PoE-out manual.

Code Block
[admin@Controller] > interface bridge port-controller port poe print
 # NAME                                    DEVICE
 0 pe1-ether1                              pe1
 1 pe1-ether2                              pe1
 2 pe1-ether3                              pe1
 3 pe1-ether4                              pe1
 4 pe1-ether5                              pe1
 5 pe1-ether6                              pe1
 6 pe1-ether7                              pe1
...
[admin@Controller] > interface bridge port-controller port poe monitor pe1-ether2,pe1-ether3
               name: pe1-ether2 pe1-ether3
     poe-out-status: powered-on powered-on
    poe-out-voltage: 52.8V      52.9V
    poe-out-current: 123mA      95mA
      poe-out-power: 6.4W       5W

Port Extender settings