  • Open the bottom lid (see "Bottom Lid28606557");
  • Connect all served devices to Ethernet ports;
  • Connect the device to the power source (see "Powering28606557");
  • Once connected to the same network, open https://192.168.88.1 in your web browser to start configuration, user name: admin and there is no password by default;
  • Once connected configure the device, so it has an active Internet connection https://mt.lv/configuration;
  • Upgrade the RouterOS software to the latest version https://mt.lv/upgrade;
  • Set up your router password in the bottom field of the QuickSet menu, to the right and repeat it, it will be used to login next time.

...

The device can be discovered using Winbox utility, by clicking on the Neighbors list. The default management address is 192.168.88.1. To reach both devices needs to be in the same IP network. Configured as a bridge, ARP, and fast forward enabled. RSTP protocol activated.
RouterOS includes many configuration options in addition to what is described in this document. We suggest starting here to get yourself accustomed to the possibilities: https://mt.lv/help.
For recovery purposes, it is possible to boot the device for reinstallation, see section Buttons and Jumpers 28606557.

Powering

The device accepts power in the two ways following ways:

...

  • Max out per port when input greater than 30 V - 1.1 A.
  • Max out per port when input lower than 30 V – 0.6 A.
  • Max total out 2.8 A.
Info

When using both the high and low Voltage adapters, the netPower will automatically choose the correct PoE standard and Voltage, based on the devices you connect to each port

Connecting to a PoE Adapter, only to deliver power to other devices:

...