Image Added

APA-1

APA-1 is an Automotive Power Adapter with overvoltage protection and other safety
features to protect your LtAP and other devices from aggressive vehicle environments. 

...

Safety information

  • Before you work on any MikroTik equipment, be aware of the hazards involved with electrical circuitry, and be familiar with standard practices for preventing accidents. The installer should be familiar with network structures, terms, and concepts.
  • This equipment is to be installed by trained and qualified personnel, as per these installation instructions. The installer is responsible for making sure, that the Installation of the equipment is compliant with local and national electrical codes. Do not attempt to disassemble, repair, or modify the device.
  • We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your own risk!
  • In the case of device failure, please disconnect it from power. The fastest way to do so is by unplugging the power adapter from the power outlet.
  • Contact time to touch PSU will be (> 1 s and < 10 s).
  •  

Information

Technical specifications, brochures, and more info about products at https://mikrotik.com/products
If you need help with configuration or installation, please seek a consultant https://mikrotik.com/consultants

Powering 

Image Removed

The device accepts power from an AC source:

Input: 100-240V ~ 50/60Hz.
Image Removed Output: 

...

  • Number of DC inputs 1 (3-pin terminal);
  • Min voltage 12 V;
  • Max voltage 48 V;
  • Max power consumption with attachment 100 W.

Installation

Input and output connection scheme:

Image Added

Voltage selection jumper scheme:

Image Added

*Place jumpers according to picture for appropriate voltage.

Installation

For installation Use a CU wire of at least 1.2 square millimeters for the DC output.
On the input side, 100-240V ~ 50/60Hz connect MTP250 series PSU to RCD.

Image Removed

Mounting

  • Use provided steel clamp and guide through holes then bracket and attach to the wall with screw, secure the device to the mast.
    Image RemovedOr use provided screws and secure device to the wall, use dowels depending on the wall materialin bracket.
    Image Added

  • Dimensions 86 x 16 x 31 mm.
  • Operating temperature -40°C to +85°C.

Accessories

The package includes:CLAMP1-2_ Hose Clamp SUS304 (Philips type; 9mm; clamping diameter range 25-70mm) with EPE bag.
SET1_ K-77

  • Fastening set.

...

Operating temperature: -40°C to 70°C 

Ingress Protection - IP 67

Image Removed
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.

Symbols on the Product

Image Added

The following symbols may appear on the product:

  • Surface may get hot.
  • CE marking.
  • HIGH VOLTAGE: This symbol indicates high voltage. It calls your attention to items or operations that could be dangerous to you and other people operation this equipment. Read the message and follow the instructions carefully.
    Image Removed
  • Double insulated.
    Image Removed
  • Do not dispose of electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased.

...