- Download the latest version of SwitchOS software from https://mikrotik.com/download;
- Connect your computer to one of the Ethernet ports;
- Connect the device to the power supply;
- Set the IP address of your computer to 192.168.88.2;
- Open your web browser, the default IP management address is 192.168.88.1, with username: admin and no password (or, for some models, check user and wireless passwords on the sticker);
- Upload a file with the web browser in the Upgrade tab, the device will reboot after the upgrade;
- Set your password to secure your device.
...
UKCA marking
(EN) Technical Specifications / (DE) Technische Spezifikationen / (FR) Spécifications techniques / (IT) Specifiche tecniche / (ES) Especificaciones técnicas / (RU) Технические характеристики: | ||||
---|---|---|---|---|
(EN) Product Power Input Options (DE) Produkt Stromquellen Optionen | (EN) Power Adapter Output Specification (V/A) (DE) Ausgangsspezifikationen des Gleichstromadapters, (V/A) | (EN) Degrees of protection provided by enclosure (IP Code) (DE) IP-Klasse des Gehäuses | (EN) Operating Temperature (DE)Betriebstemperatur | |
Voltage, V | Current, A | |||
DC Jack (36 - 57 V DC) PoE in Ethernet Port (42.5 - 57 V DC) 2 - PIN Terminal (36 - 57 V DC) | 48 | 0.95 | IP66 | -40°..+70°C |