RB5009UPr+S+IN


Safety Warnings

Before you work on any equipment, be aware of the hazards involved with electrical circuitry, and be familiar with standard practices for preventing accidents.
Ultimate disposal of this product should be handled according to all national laws and regulations.
The Installation of the equipment must comply with local and national electrical codes.
This unit is intended to be installed in the rackmount. Please read the mounting instructions carefully before beginning installation. Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation for people and damage to the system.
This product is intended to be installed indoors. Keep this product away from water, fire, humidity, or hot environments.
Use only the power supply and accessories approved by the manufacturer, which can be found in the original packaging of this product.
Read the installation instructions before connecting the system to the power source.
We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your own risk!
In the case of device failure, please disconnect it from power. The fastest way to do so is by unplugging the power plug from the power outlet.
It is the customer's responsibility to follow local country regulations, including operation within legal frequency channels, output power, cabling requirements, and Dynamic Frequency Selection (DFS) requirements. All Mikrotik devices must be professionally installed.

Setup

Powering

The power consumption under maximum load can reach 150 W. The device accepts power from the power jack, 2-pin terminal, or from any Ethernet port:

Mode B: Ethernet port 2 - 8.
Pins 4 & 5 = DC+
Pins 7 & 8 = DC-

Connecting to a POE Adapter:

  1. Connect the Ethernet cable from the device to the POE port of the POE adapter.
  2. Connect an Ethernet cable from your LAN to the LAN port of the POE adapter, please mind arrows for data and power flow.
  3. Connect the power cord to the adapter, and then plug the power cord into a power outlet.

Configuration

Once logged in, we recommend clicking the "Check for updates" button in the QuickSet menu, as updating your RouterOS software to the latest version ensures the best performance and stability. For wireless models, please make sure you have selected the country where the device will be used, to conform to local regulations.
RouterOS includes many configuration options in addition to what is described in this document. We suggest starting here to get yourself accustomed to the possibilities: https://mt.lv/help. In case an IP connection is not available, the Winbox tool (https://mt.lv/winbox) can be used to connect to the MAC address of the device from the LAN side (all access is blocked from the Internet port by default).
For recovery purposes, it is possible to boot the device for reinstallation, see section Buttons and jumpers.

Mounting

The device is designed to use indoors and it can be mounted on the wall, or it can be placed on the desktop. 

  1. Find the designed mounting holes on both sides of the device, as shown in the picture;
  2. Use provided screws to secure the device to the wall;
  3. Based on the wall material you can use a drill bit and provided dowels.

The device has no protection from water contamination, please ensure the placement of the device in a dry and ventilated environment.
We recommend Cat6 cables for our devices.
The mounting and configuration of this device should be done by a qualified person.

Rackmount

If desired placement is rackmount, additional brackets can be purchased separately:

RB5009 rackmount kit K-79

Extension slots and ports

Buttons and jumpers

The RouterBOOT reset button has the following functions. Press the button and apply the power, then:

Regardless of the above option used, the system will load the backup RouterBOOT loader if the button is pressed before power is applied to the device. Useful for RouterBOOT debugging and recovery.

LED

Accessories

The package includes the following accessories that come with the device:

Please visit wiki pages for the MikroTik SFP module compatibility table: https://wiki.mikrotik.com/wiki/MikroTik_wired_interface_compatibility

Operating system support

The device supports RouterOS software version 7 and higher. The specific factory-installed version number is indicated in the RouterOS menu /system resource. Other operating systems have not been tested.


To avoid pollution of the environment, please separate the device from household waste and dispose of it in a safe manner, such as at designated waste disposal sites. Familiarize yourself with the procedures for the proper transportation of the equipment to the designated disposal sites in your area.


Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance.

Innovation, Science and Economic Development Canada

This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device.

L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 1) L’appareil ne doit pas produire de brouillage; 2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe [B] est conforme à la norme NMB-003 du Canada.

CAN ICES-003 (B) / NMB-003 (B)

UKCA marking                         

(EN) Technical Specifications / (DE) Technische Spezifikationen / (FR) Spécifications techniques / (IT) Specifiche tecniche / (ES) Especificaciones técnicas / (RU) Технические характеристики:

(EN) Product Power Input Options

(DE) Produkt Stromquellen Optionen
(FR) Options d'entrée d'alimentation du produit
(IT) Opzioni di ingresso alimentazione del prodotto
(ES) Opciones de entrada de energía del producto
(RU) Параметры входной мощности продукта

(EN) Power Adapter Output Specification 

(DE) Ausgangsspezifikationen des Gleichstromadapters
(FR) Spécifications de sortie de l'adaptateur de courant continu
(IT) Specifiche di uscita dell'adattatore di corrente continua
(ES) Especificaciones de salida del adaptador de corriente continua
(RU) Выходные характеристики адаптера постоянного тока

(EN) Degrees of protection provided by enclosure (IP Code)

(DE) IP-Klasse des Gehäuses
(FR) Classe IP du boîtier
(IT) Classe IP della custodia
(ES) Clase de IP del recinto
(RU) Класс защиты корпуса IP

(EN) Operating Temperature

(DE)Betriebstemperatur
(FR) température de fonctionnement
(IT) temperatura di esercizio
(ES) Temperatura de funcionamiento
(RU) Рабочая Температура

Voltage, VCurrent, A

DC Jack (24 - 57 V DC)

PoE In Ethernet Port (24 - 57 V DC)

2-pin terminal (24 - 57 V DC)


48 V


2 A


IP20


±0°..+60°C


Information contained here is subject to change. Please visit the product page on www.mikrotik.com for the most up-to-date version of this document.