Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

UP1302C-12 internal power supply.

Usage

CCR2116, CCR1036 r2, CRS326-24S+2Q+.

Specifications

Open frame PSU 12 V DC ⎓ 10.8 A 130 W, 90-264 Vac 90 % 55x106x34 mm.

...

  1. Use a wrist grounding strap when unpacking and working with electrical components to avoid electrical discharge (ESD) damage;
  2. Remove the top cover from the device to access the power supply unit;
  3. Unplug wires from the supply unit leading to PCB;
  4. Unscrew four screws and remove the old unit;
  5. Place UP1302C-12 into the CCR device and secure it with previously removed screws;
  6. Attach the supply cable to the white connector;
  7. Install to cover into its original position and secure with screws.

...

Info
Note. The information contained here is subject to change. Please visit the product page on www.mikrotik.com for the most up-to-date version of this document.